Operating lamp,Operating table,Patient beds suppliers

BPM-A202 Anesthesia Machine with Ventilator

With Ventilator

  • Model: BPM-A202
  • MOQ: 1
  • Payment Terms: T/T,L/C,D/A,D/P,Western Union,Money Gram,PayPal

BPM-A202 Anesthesia Machine with Ventilator

Features:

  • The high-precision Vaporizer is designed with a stable concentration output, automatic compensation for pressure, temperature and flow rate. And it is available to choose one kind of gas from Halothane, Enflurane, Isoflurane, and Sevoflurane, ensuring a successful anesthesia operation;
  • Reliable pneumatic transmission system;
  • Economic and proper configuration of technologies, optional as required by the Customer;
  • Modularized design and upgrading. Upgrading is available as required by the Customer.

Specification:

Main body

High-strength engineering plastic rack, light, beautiful and corrosion resistant

Scope of application

adult, child

Gas source

O2, N2O: 0.270.55MPa

Flow meter

O2: 0.11.0L/min; 1.110L/min

Flow rate of rapid oxygen supply

2575L/min

Low oxygen pressure alarm

There will be sound alarm when the oxygen

pressure < 0.2MPa

Vaporizer

it has the function of automatic compensation based on pressure,temperature,and flow rate. The regulation range of evaporator concentration is 05 vol%;

Among Halothane,Enflurane,Isoflurane and Sevoflurane,one can be chosen for application as required by the customer.

Respiratory circuit 

working mode: all-close, semi-close, semi-open;

releasing pressure: 0.57 kPa

Respiratory bellows

bellows for adults, bellows for children

tidal volume range:01500 ml

Part of Ventilator

Display mode

High-definition 4.8” LCD screen display

Ventilation  mode

IPPV, MANUAL (Manual monitoring of tidal volume, ventilation volume, respiratory rate)

Ventilation parameters

Tidal volume         501500ml

Rate                480 bpm

I:E                  2:11:4

Pressure range        1.06.0 kPa

Parameters for ventilation monitoring

tidal volume, ventilation volume, IPPV rate, I/E, peak pressure of airway, inspiratory trigger pressure, pressure - time waveform

Security Alarm System

1. Airway pressure alarm :

upper limit setting range: 1.06.0 kPa;

low limit setting range: 0.42.0 kPa.

2. TV alarm:

upper limit setting range 0.52.0L;

low limit setting range: 0.021.0L. 

3. Sustained high-pressure alarm: it will give alarm when stress have consistently been higher than 2.5 kPa.

4. Suffocation alarm: it will give sound and light alarm if there is

no tidal volume input in 15s.

5. Power alarm

Power

AC 220V±10%     50Hz±1Hz


BPM is the best anesthesia machine supplier. Welcome your inquiry.


24h at Service