BPM-A204 Anesthesia Machine with Ventilator
With Ventilator
- Model: BPM-A204
- MOQ: 1
- Payment Terms: T/T,L/C,D/A,D/P,Western Union,Money Gram,PayPal
BPM-A204 Anesthesia Machine with Ventilator
Features:
- The Ventilator adopts microcomputer control with high-definition TFT color LCD display, integrating the functions of respiratory control and displaying the monitoring parameters. It is versatile in function and excellent in performance;
- The high-precision Vaporizer is designed with a stable concentration output, automatic compensation for pressure, temperature and flow rate. And it is available to choose one kind of gas from Halothane, Enflurane, Isoflurane, and Sevoflurane, ensuring a successful anesthesia operation;
- High-definition four-tube flowmeter, designed with stoppers for oxygen and nitrous oxide to control the output oxygen concentration;
- Reliable pneumatic transmission system;
- Economic and proper configuration of technologies, optional as required by the Customer;
- Modularized design and upgrading. Upgrading is available as required by the Customer.
Specification:
Main body High-strength engineering plastic rack, light, beautiful and corrosion resistant Scope of application adult, child Gas source O2, N2O: 0.27~0.55MPa Flow meter O2/N2O: 0.1~1.0L/min, 1.1~10L/min; N2O: 0.1~1.0L/min, 1.1~10L/min. O2, N2O linkage and N2O Stopper When using nitrous oxide, oxygen concentration>25%; When the oxygen pressure<0.2MPa, the flow of nitrous oxide would be cut off. Flow rate of rapid oxygen supply 25~75L/min Low oxygen pressure alarm There will be sound alarm when the oxygen pressure < 0.2MPa Vaporizer it has the function of automatic compensation based on pressure,temperature,and flow rate. The regulation range of evaporator concentration is 0~5 vol%; Among Halothane,Enflurane,Isoflurane and Sevoflurane,one can be chosen for application as required by the customer; Vaporizers that are imported with original packaging are also available. Respiratory circuit working mode: all-close, semi-close, semi-open; releasing pressure: 0.5~7 kPa Respiratory bellows bellows for adults, bellows for children tidal volume range: 0~1500 ml Part of Ventilator Display mode High-definitionTFT or color LCD screen display Ventilation mode IPPV,SIPPV,SIMV,PEEP,MANUAL,SIGH(IMV, VCV, PCV) Ventilation parameters Tidal volume 50~1500ml(20~1500ml) Rate 1~99 bpm SIMV rate 2~20bpm I:E 2:1~1:8 (4:1~1:8) Inspiratory trigger pressure -1.0~2.0 Kpa PEEP 0~2.0 Kpa Pressure range 1.0~6.0 Kpa SIGH 1.5 times the inspiratory time(70-150 adjustable) Parameters for ventilation monitoring tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, average pressure, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure, Inspiratory platform (autonomous inspiratory rate, lung compliance, airway resistance,flow-volume loop, pressure-volume loop) Monitoring of oxygen concentration 21%~100% Security Alarm System 1. Oxygen Concentration alarm: upper limit setting range (21%~100%); low limit setting range (10%~80%). 2. Airway pressure alarm: upper limit setting range 0.3~6.0 kPa; low limit setting range 0.2~5.0 kPa. 3. Per-minute ventilation volume alarm: upper limit setting range 3.0~30L/min; low limit setting range 1.0~10L/min. 4. Sustained high-pressure alarm:it will give alarm when stress have consistently been higher than 2.5 kPa. 5. Suffocation alarm: it will give sound and light alarm if there is no tidal volume input for 15 seconds. 6. Power alarm. Power AC 220V±10% 50Hz±1Hz (UPS, Storage battery) Mechanical Arms End-expiratory CO2 monitoring
BPM is the best anesthesia machine supplier. Welcome your inquiry.
24h at Service
[email protected] WhatsApp:+8613598095446, +8615639080652