BPM-M801 Portable Patient Monitor

8” Color TFT Screen

  • Model: BPM-M801
  • MOQ: 1
  • Payment Terms: T/T,L/C,O/A ,Western Union,PayPal

BPM-M801 Portable Patient Monitor

Features:

  • 8" color TFT LCD screen, resolution 800*600 
  • Waterproof design, resistance to dropping (1 meter) 
  • Low power consumption, fanless structure which creates no noise
  • Support external 13-20V DC power, continuously working for 5.5 hours above on battery backup, full charge with 2.5 hours, suitable for Ambulance, Emergency Transport
  • Display mode: Big font, trends review, 7 leads ECG waveform on same screen, and etc 
  • 15 kinds of arrhythmia analysis, 15 kinds of drug concentration analysis
  • Anti-electrosurgical unit (300W), anti-defibrillation (360J), suitable for Operating Room, General Ward
  • Digital SpO2 technology, excellent anti- interference performance, low perfusion (0.1%)

Specification:
 

ECG

Lead

Standard 3/5 lead

Lead Mode

5 Leads (RA, LA, LL, RL,V) 

Lead Selection

 I, II, III, avR, avL, avF, V

Lead Mode

3 Leads (RA, LA, LL) 

Lead Selection

I, II, III

Gain

2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV


HR and Alarm Range

Adult: 15 ~ 300 bpm
Ped/Neo: 15 ~ 350 bpm

Accuracy

±1% or±1bpm, which is greater

Resolution

1 bpm 

Sensitivity

> 200 (uVp-p)

Differential Input Impedance

> 5 MΩ


Bandwidth

Surgery    1 ~ 20 Hz
Monitor     0.5 ~ 40 Hz
Diagnostic  0.05 ~ 130 Hz


CMRR

Monitor > 100 dB 
Operation > 100 dB 
Diagnosis > 90 dB

Electrode Offset Potential

±300mV 

Range

±2 mV ~ ±700 mV

Width

0.1 ms ~ 2 ms

Rise time

10 us ~ 100 us


ST Segment Monitoring Range

 Measurement Range: -2.0 ~ +2.0 mV
 Measurement Accuracy: -0.8 ~ +0.8 mV
 Measurement Error: ±0.02 mV or ±10%

 

RESP

Method

Impedance Between RA-LL or RA-LA

Measuring Impedance Range

0.3~3 Ω

Base line Impedance Range

200~4 KΩ

Bandwidth

0.1~2.5Hz

Resp. Rate



Measuring and Alarm Range

Adult: 2 ~ 120 BrPM 
Neo/Ped: 2 ~ 150 BrPM 
Resolution: 1 BrPM 
Accuracy: ±2 BrPM
Apnea Alarm: 10 ~ 40 S

 

NIBP 

Method

Oscillometric

Mode

Manual, Auto, STAT  

Measuring Interval in Auto Mode

1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)

Measuring Period in STAT Mode

5 Min

Pulse Rate Range

40 ~ 240 bpm

Measuring and Alarm Range


Adult Mode

SYS 40 ~ 270 mmHg 
DIA 10 ~ 215 mmHg 
MEAN 20 ~ 235 mmHg  


Pediatric Mode

SYS 40 ~ 200 mmHg 
DIA 10 ~ 150 mmHg 
MEAN 20 ~ 165 mmHg


Neonatal Mode

SYS 40 ~ 135 mmHg 
DIA 10 ~ 100 mmHg 
MEAN 20 ~ 110 mmHg

Static Pressure Range

 0 ~ 300 mmHg

Static Pressure Accuracy

±3mmHg


Accuracy

Maximum Average Error ±5mmHg
Maximum Standard Deviation ±8mmHg


Overpressure Protection

Adult Mode: 300 mmHg 
Pediatric Mode: 240 mmHg 
Neonatal Mode: 150 mmHg

  

Dimension

210*80*175mm (L*W*H)

Weight

1.35kg

Standard

 3/5-Lead ECG, RESP, SpO2, NIBP, PR, 1-TEMP

Optional

Mainstream/Sidestream EtCO2, Touch screen


24h at Service