BPM-MR100 Mobile X Ray Machine
Main Features:
- This efficiency-improved x ray machine takes the following advantages:
- Adopts high-pressure silicon, full-wave rectification technology.
- With kilovolt (kV), milliampere (mA) and time (s ) three factors interlocks control system
- Overloading indicator & the protection circuit of excessive voltage & insufficient voltage, thus the X ray tube head of x ray will not be damaged because of mis-operating.
- Equipped with steady filament voltage circuit to control the X ray dosage while photographing
- Remotely controlled exposure & manually controlled exposure options
- Sound & flash indicator while exposing for patients & medical personnel convenience
- This x ray machine equipped the electricbeam limiter with shadow positioning. The electric beam limiter will send out a beam of visual light while operating to aim the nidus and the scale ofthe visual light overlaps ,the scale of X ray exposing. This function make it convenient that medical personnel position the nidus & the x ray exposed area.
- Movable cantilever sliding in vertical direction so that it is flexible to adjust the Xray tube head to appropriate angle & height. When the complete machine is moved, the cantilever of theXray tube head can be set to the min. position and lock, safely and conveniently.
Specification:
- This machine is a single focus point, full-wave rectification bedside X ray medical diagnosis machine
- Maximum Ratings:
mA kVp s
kV S |
~3.2
|
~4.0 |
~6.3 |
16 | 90 | 90 | 90 |
32 | 90 | 90 | 90 |
63 | 90 | 90 |
|
100 | 80 |
|
- Condition of the power supply Single-phase alternating current Voltage: 180V-250V Frequency: 50Hz Power supply resistance ≤0.2Ω Instantaneous electric current: 37A (Max)
- Timer 0.08-6.3s, 20 shelves of electron type 5. X ray tube specification : XD4-29/100, focus 4.3
- X ray tube focus highest position (above ground level)≥1710mm
- X ray tube focus lowest position (above ground level)≤480mm
- Remotely exposure distance: 6m
- The required pulling force to move the whole machine≤25kg
- Power of Electric Beam Limiting Device: AC 24V, Capacity 110W.
- Indicator Power of Electric Beam Limiting Device: AC 24V, Power: 100W, Tungsten Haloid Light
- Illuminance of Electric Beam Limiting Device: no less than 100Lx at 1m from X ray focus to target area
- When X ray focus at 650mm away from the film, max illumination scale ≤350mm×350mm;
- When X ray focus at 1m away from the film, max illumination scale ≤50mm×50mm